NMD90, calibre 6/3, 150 m, bobine, blanc, CSA, 300 V, 65 A.
Vous pourriez aussi aimer
Tesla wall Charger Install : Can 6/3 wire be used for tesla Wall Charger? Using 60 Amp Breaker, 220 Volt . can this be used if it has 300 Volt Rating wire or should go 600Volt rating wire ?
We are happy to help! For specific usage of this wire, please contact our experts at CableTechSupport@southwire.com to better answer your question!
Date de publication: 2022-02-01
What is the maximum amp rating of this cable?
60amps
Date de publication: 2021-11-07
Can you use this for stove electric hook up?
Not normal, as it is more strong, expensive, you are wasting money, unless you have a special stove such as induction or other that require a thicker cable.
Stove cable is normally NMD 90 8(3) or AC 90 8(3).
Date de publication: 2021-09-24
I need to install a 40 A panel about 15 meters from my main panel, what size wire should I use? I was told “stove cable”, whatever that is!
I am wondering if you could find a 40 Amp panel, unless you are referring to a pony panel that contain up to 4 circuits. In any circumstances you can not draw more than %80 of the total amp allowed by the load center(panel). This means you could use couple of 15 Amp circuit breakers. In answering your question, which is not properly asked, as you needed to indicated what you plan to feed by this proposed load center, is "Yes", NMD 90 8(3) or (Stove Cable), could handle up to maximum 40 Amps or the feeder. Make sure that you protect the cable by a double pole breaker not exceeding 40 Amps. Do not forget to limit the load to maximum 32 Amps total that could possibly be drawn from this sub-panel or load center.
Date de publication: 2021-09-24
I need to purchase about 60 feet of NDM90 6/3 wire for a Hot tube connection protected by a 60 Amp breaker, can you please indicate the amperage rating for this wire,
Please reach out to out team at CableTechSupport@southwire.com
Date de publication: 2021-06-07
I have 100 amp main panel. Can I use this wire for a feeder to a 100amp subpanel next to main with 50 amp breaker in main?
Thanks for the question. Please reach out to our cabletechsupport@southwire.com team for additional support.
Date de publication: 2021-09-14
I need almost 20 meter so what should i do?
Dear Valued Lowe’s Customer, to better answer your question, please contact our customer service department at 1-888-98LOWES (56937). Call any day between 8:30 AM and 7:00 PM, or call your local store for further assistance.
Date de publication: 2021-05-04
What is the voltage rating for this cable?
300 volts
Date de publication: 2021-03-09
Fil électrique NMD90 de Southwire, 150 m, 6 AWG, blanc est évalué
de
5 de
2.
Rated 5 de
5
de
CalgaryDoug par
As ordered
What can I say? It's wire. Cut and delivered as ordered.
Date de publication: 2020-11-11
Rated 5 de
5
de
Donk par
Perfect
I had difficulty finding this wire locally and was very happy to be able to order it from Lowes. Shipping was prompt and free!
Date de publication: 2017-02-08