Description
Main lugs loadcentres typically are used as an add-on load center and is connected to the service entrance loadcentre when spaces for more circuits are needed or when a main disconnect is located elsewhere. It does not contain a main breaker. 8 Spaces, expandable to 15 circuits maximum with the use of QO Tandem breakers. Type 1 Indoor Enclosure with surface mounted trim. CSA approved for vertical, horizontal or inverted mounting. Accepts aluminum or copper conductors. Main Wire Size - AWG/kcmil Al/Cu: #8-1.
- 1 Phase, 3 wire, 120/240VAC
- 8 Spaces, expandable to 15 circuits maxi
- Type 1 indoor enclosure with combination flush and surface trim to meet all mounting situations
- CSA approved for vertical, horizontal or inverted mounting
- Accepts aluminum or copper conductors
- Main wire size - AWG/kc mil aluminum/copper : #8-1
- Includes latch door on the cover
- CSA approved to only accept Canadian Square D QO circuit breakers
Product specifications
Amperage
100
Brand/Model Compatibility
Fits most
Buss Bar Construction
Aluminum and copper
Circuits
15
Cover Included
Yes
Depth(cm)
9.525
Depth(in)
3.75
Depth(mm)
95.25
Feed-Through Lugs
Yes
Ground Bar Installed
Yes
Height(cm)
32.385
Height(in)
12.75
Height(mm)
323.85
Manufacturer Color/Finish
Gray
Mounting Type
Surface
Number of Spaces
8
Orientation
Over/Under
Paintable
Yes
Phase Type
Single phase (120/240)
Plug-On Neutral
No
Series Name
N/A
Use Location
Indoor
Value Pack
No
Value Pack Contents
Not apply
Width(cm)
22.86
Width(in)
9
Width(mm)
228.6
You may also like
If the ground bar is not included; why does it say that it is in the specs.?
Hi,
On QO816L100S the ground bar needs to be purchased separately, Ground Bar - PK7GTA.
Regards, Schneider Electric Customer Care
Date published: 2022-08-31
If the ground bar is not included; why does it say that it is installed in the specs.?
Hi,
On QO816L100S the ground bar needs to be purchased separately, Ground Bar - PK7GTA.
Regards, Schneider Electric Customer Care
Date published: 2022-08-31
Does this box have a neutral bar and a ground bus bar?
Hello,
The QO8L100S includes the neutral bar factory installed. The ground bar is not included.
Regards, Schneider Electric Customer Care.
Date published: 2022-08-30
I'm a little confused: This is a 100 amp panel, but the description says that the "main wire size" is #8 ... As I understand it, #8 wire is only rated for 50 amps, so how am I supposed to feed 60 (or more) amps to this thing if I can only #8 feeder cable?
It's not well explained at a DIY'er level in the description above, but the wire size mentioned is a range that the panel (and lugs) can handle - in this case from a minimum of #8 to a maximum of #1.
Date published: 2018-11-21