Description
Stab-lok breakers are fully interchangeable with all past breakers and deliver the same proven quality. The unique Stab-lok breaker design of only a 1/2 thick per pole, allows for the reduction of the size and weight of the loadcentre. This breaker will work only in Federal Pioneer Stab-lok branded residential panels. Typical application for a double pole 100 Amp breaker include an electric range (240V up to 3.75kw) in a home and requiring a wire size of 8-3. Provides overload and short circuit protection (240Vac). 10,000 Amperes Interrupting Rating (AIR). Lug Range: #14 - #6. Provides Slot/Robertson screws.
You may also like
Will this work with in a Federal Pacific panel? I have some other Federal Pioneer breakers that are in it now.
Other than approval, yes they will work perfectly.
Date published: 2018-02-02
Hi! Would this be ok for replacing the main switch on a 100amp. federal pioneer fuse box. The interior have been change for stab-lock brakers years ago without changing the main switch, witch was not in store around here.
Sorry, the part in question is a branch breaker, not a main breaker. If you are looking for a Federal Pioneer 100A Main breaker, then the part number is a 1C100. This is not a stock item, but would have to be ordered as a special order.
Date published: 2017-07-05
How to install this breaker in my BE120-40-2C200 40CT 2P3W200A PANELW/MAI I need this 100 amp to feed my 100 amp square D sub panel an where I put this breaker
This breaker is a NA type breaker that will fit your BE panel. It takes 4 spaces in the panel so make sure you have enough spaces in the panel. The NA breaker will fit anyware in the panel with no issues.
Date published: 2017-06-26
100-A 2P (NC) Circuit Breaker is rated
out of
5 by
1.
Rated 5 out of
5
by
Amblair506 from
Great price
I ordered this breaker to replace a worn out one came before I was expecting it, and it will save me a ton of time compared to changing the whole box .
Date published: 2020-10-25